Feel free to call us for more information
400-808-1508
Product Model:HF-1L
Product Quote:
Related Products:
Application
HF-series variable frequency speed glass reactor is mainly used for the synthesis reaction of materials. By injecting a certain temperature of circulating liquid into the interlayer of the reactor, the sample in the reactor can react at the required temperature. According to needs, the kettle can be evacuated to make the sample react under negative pressure. The uniform dripping of sample can be controlled by adjusting the regulating valve on the outlet pipe of the constant pressure funnel. The heat exchange function of the condenser can be used to distill and recover the reaction product.
Main Features
The glass parts are made of high borosilicate glass, which has excellent corrosion resistance, high temperature and low temperature resistance, and low linear expansion coefficient, which can withstand large thermal shocks
Detachable, no dead space discharge valve, convenient for the discharge of reactor sample
Standardized connection method, convenient and quick to disassemble
The temperature vacuum test unit is convenient to accurately grasp the temperature and vacuum degree in the kettle
Under vacuum state, negative pressure can reach 0.095Mpa
Overhead agitator and equipped with imported agitating bearing sleeve
All parts in contact with liquid are made of high borosilicate glass or PTFE, which has excellent corrosion resistance
Equipped with 316 stainless steel receiving tray for easy receiving
Technical Parameters
Model | HF-1L |
Effective volume in the kettle | 1L |
Jacket volume of kettle | 0.3L |
Condenser condensing area | 0.025m2 |
Constant temperature funnel volume | 200ML |
Stirring insertion hole | 24# Standard connector |
Temperature sensor insertion hole | 24#Standard connector |
Condenser connection port | 24#Standard connector |
Liquid filling port | 19#Standard connector |
Constant pressure funnel interface | 24#Standard connector |
Glass components | Borosilicate glass 3.3 |
Operating temperature | -80~200℃ |
Limit of temperature difference between inside and outside of the kettle | ≤80℃ |
Pressure in the kettle | -0.1~0.0 |
Jacket pressure | ≤+0.03 |
Vacuum system lifting rate | ≤2kPa/h |
Speed mode | Coarse and fine adjustment |
Speed Range | 50-500rpm |
Speed display | LCD |
Timing range | 1-9999min |
Mixing time setting | Yes |
Speed display resolution rpm | ±1 |
Speed memory | Yes |
Maximum torque | 70N.cm |
Maximum viscosity | 10000cps |
Stirring paddle fixing method | Self-locking chuck |
Drill chuck clamping diameter range | 0.5-10 |
Overload protection | Display failure and stop automatically |
Motor protection | Display failure and stop automatically |
Additional motor power | 70W |
sensor type | Pt100 |
Temperature display accuracy | ±0.1℃ |
Seal material | PTFE |